Abstract

ABSTRAK SIMULASI PERUBAHAN TEMPERATUR BERDASARKAN VARIASI DAYA DAN ALIRAN PADA HEATER KONTAK LANGSUNG UNTAI FASSIP MENGGUNAKAN SOFTWARE ChamCAD versi 6.4.1. Untai FASSIP merupakan fasilitas eksperimen dimana aliran fluida pada sistem tersebut bergerak dengan sendiri karena adanya perbedaan temperatur pada dua sisi yang berbeda. Sirkulasi alami merupakan kemampuan fluida untuk bersikulasi secara berkesinambungan yang disebabkan oleh perbedaan kerapatan densitas fluida karena adanya beda temperatur. Salah satu komponen utama untai FASSIP adalah digunakannya heater sebagai sumber panas. Untuk mendapatkan panas yang sesuai dengan yang dibutuhkan pada untai FASSIP memerlukan heater sebagai sumber panasnya. Tujuan penelitian adalah mendesain dan menghitung serta menentukan besaran diameter kawat kanthal yang digunakan agar kebutuhan panas dan capaian temperatur yang diinginkan dapat dipenuhi. Metode yang digunakan adalah dengan cara melakukan perhitungan besaran resistan dan panjang kawat kanthal, dengan cara menentukan terlebih dahulu besaran diameter dan daya yang digunakan pada kawat kanthal tersebut. Penentuan besaran temperatur dilakukan dengan cara memvariasikan daya dan aliran menggunakan program ChamCAD versi 6.4.1. Hasil desain untuk heater kontak lansung yang menggunakan kawat kanthal dengan diameter 2 mm dan daya maksimum sebesar 5 kW, didapat panjang kanthal sepanjang 17,623 meter. Hasil simulasi dengan daya 1 kW didapat flowrate 0,1 liter/menit sebesar 113,34o C dan pada flowrate 1,0 liter/menit sebesar 41,33o C. Kata kunci: Heater, Untai FASSIP, Software ChamCAD 6.4.1 ABSTRACT SIMULATION OF TEMPERATURE CHANGE ON DIRECT CONTACT HEATER IN FASSIP LOOP BASED ON FLOW AND POWER VARIATION USING ChamCAD version 6.4.1. FASSIP loop was an experimental apparatus in which the fluid flow in the fluid flow of the system can move by itself due to temperature differences. The natural circulation of the fluid's ability to circulate continuously caused by differences in the density of the fluid density because of the temperature difference. One of the main components FASSIP strand is the use of heater as the heat source. To get the heat as required on the strand FASSIP require a heater as the heat source.The purpose of research is to design and calculate and determine the magnitude of the diameter of the wire used kanthal that heat needs and achievements of the desired temperature can be met.The method used is a way to quantify the long-wire resistance and kanthal, by determining in advance the amount of diameter and power used in the kanthal wire. While determining the amount determined by the variation of temperature and flow power using version 6.4.1 ChamCAD program. Results for the design of direct contact heater that uses kanthal wire with a diameter of 2 mm and a maximum power of 5 kW, obtained kanthal along 17.623 meter length. The simulation results obtained with power 1 kW flowrate of 0.1 litre/minute for 113,34o C and at a flowrate of 1.0 litre/minute for 41,33o C Key words: Heating, Loop FASSIP, Software ChamCAD 6.4.1

Item Type: Conference or Workshop Item (UNSPECIFIED)
Subjects: Keselamatan dan Keamanan Nuklir
Divisions: Pusat Teknologi dan Keselamatan Reaktor Nuklir
Depositing User: USER PTKRN BATAN
Date Deposited: 08 May 2018 03:14
Last Modified: 08 May 2018 03:14
URI: http://repo-nkm.batan.go.id/id/eprint/1127

Actions (login required)

View Item View Item