ABSTRAK PERHITUNGAN KEKUATAN LASAN PADA PENYANGGA TANGKI PEMANAS DAN TANGKI PENDINGIN DI UNTAI FASSIP-01. perhitungan kekuatan las didasari pada pertimbangan faktor keamanan dari konstruksi rangka utama dan komponen tambahan seperti tangkai pemegang untuk pendinginan dan pemanasan tangki. Kekuatan sambungan las dipengaruhi oleh; jenis bahan logam induk, jenis bahan pengisi, bentuk sambungan las yang digunakan, tinggi dan panjang sambungan las, arah dan beban seperti yang terjadi. Komponen tangkai pemegang menggunakan bahan UNP50 profil dengan ukuran 50 × 30 × 5 mm dan panjang 400 mm yang dilas ke rangka utama menggunakan jenis elektroda E7013 dengan diameter 2,4 mm. Hasil perhitungan menunjukkan bahwa jenis sambungan temu (butt-joint) mampu mendukung beban arah vertikal sebesar 652 kN, beban arah horizontal sebesar 785 kN, dan beban eksentrik sebesar 803 kN. Sedangkan penggunaan sambungan tumpang (lap-joint) mendapatkan peningkatan sebesar 40% untuk beban arah vertikal, 37% untuk beban arah horizontal, dan 47% untuk beban eksentrik, sebagai hasil perhitungan dengan memasukkan nilai faktor keamanan (safety factor). Kata kunci: kekuatan las, tangkai pemegang, tangki pemanas, tangki pendingin, FASSIP-01 ABSTRACT CALCULATION OF WELD STRENGTH BUFFER TANK TANK HEATING AND COOLING IN strand FASSIP-01 . weld strength calculation is based on a consideration of the safety of the construction of the main frame and additional components such as stems holder for cooling and heating tank. Influenced by the strength of welded joints; type of parent metal, type of filler, the shape of the weld joint is used, the height and length of the weld joint, directions and expenses as it happens. Components stalk holder uses the profile UNP50 material with a size of 50 × 30 × 5 mm and a length of 400 mm are welded to the main frame using E7013 electrode type with a diameter of 2.4 mm. The calculations show that the connection type Intersection (butt-joint) capable of supporting a load of 652 kN the vertical direction, horizontal direction load of 785 kN, and the eccentric load of 803 kN. While the use of overlapping connection (lap-joint) get an increase of 40% for loads vertical direction, 37% for load horizontal direction, and 47% for the eccentric load, to the calculation results with or without the value of the safety factor (safety factor). Keywords: weld strength, haft-holder, heating tanks, cooling tanks, FASSIP-01

Item Type: Conference or Workshop Item (Paper)
Subjects: Keselamatan dan Keamanan Nuklir
Divisions: Pusat Teknologi dan Keselamatan Reaktor Nuklir
Depositing User: USER PTKRN BATAN
Date Deposited: 14 May 2018 08:50
Last Modified: 14 May 2018 08:50
URI: http://repo-nkm.batan.go.id/id/eprint/1553

Actions (login required)

View Item View Item