ABSTRAK KARAKTERISASI ARUS TEMBUS KABEL PENGHANTAR PEMANAS PADA UNTAI FASSIP-01. Untai FASSIP-01 merupakan sebuah peralatan eksperimen dimana aliran fluidanya dapat bergerak secara alamiah karena adanya beda temperatur. Untai uji FASSIP- 01 menggunakan empat buah pemanas, daya setiap pemanasnya sebesar 5 kW. Kabel penghantar untuk daya sebesar ini harus memenuhi persyaratan arus tembus maksimal dan tahanan isolasi yang telah ditentukan. Walaupun bahan-bahan isolasi yang digunakan cukup baik dan mempunyai tahanan isolasi yang tinggi, tetapi masih ada tempat-tempat yang lemah pada lapisan isolasinya.Tujuan penelitian adalah untuk mendapatkan karakteristik arus tembus kabel penghantar yang digunakan pada untai FASSIP-01. Metode yang digunakan adalah dengan cara memberikan tegangan pada kabel penghantar mulai dari 0,5 kV s/d 5 kV, lalu dilakukan pencatatan hasil pengukuran arus tembus. Variasi tegangan 0,5 s/d 5 kV dimaksudkan untuk mendapatkan data yang lebih akurat sedangkan tegangan yang cukup tinggi digunakan untuk menentukan kekuatan bahan isolasi kabel penghantar. Hasil pengukuran arus tembus sebesar 0,193 mA s/d 2,270 mA, linear terhadap tegangan inputnya. Berdasarkan perhitungan tahanan isolasi diperoleh sebesar 2.500 kOhm, lebih tinggi dari tahanan isolasi minimal yang dipersyaratkan sebesar 242 kOhm. Kata kunci: pemanas, kabel penghantar, arus tembus, untai FASSIP-01 ABSTRACT CHARACTERIZATION FLOW THROUGH HEATER CABLE CONDUCTOR ON THE LOOP FASSIP-01. Loop FASSIP-01 was an experimental apparatus in which the fluid flow can move naturally because of the temperature difference. Loop FASSIP-01 using four heaters, the heating power of 5 kW each. Conductor cables for the power of this magnitude should meet the requirements of the current maximum translucency and insulation resistance is predetermined. Although the insulating materials used is quite good and has a high insulation resistance, but there are still places that are weak in research insulation material. The research objective is to get a current characteristic translucent conductive wires used in the loop FASSIP-01. The method used is by applying a voltage to the conductive wires ranging from 0.5 kV until 5 kV, and also recorded the current measurement results translucent. Voltage variation of 0.5 until 5 kV intended to obtain more accurate data, while a high enough voltage is used to determine the strength of the cable insulation material conductive. The measurement results translucent flow of 0.193 mA until 2.270 mA, linear with respect to the input voltage. Based on calculations obtained insulation resistance of 2,500 kOhm, higher than the required minimum insulation resistance of 242 kOhm. Key words: heating, cable conductor, flow-through, loop FASSIP-01

Item Type: Conference or Workshop Item (Paper)
Subjects: Keselamatan dan Keamanan Nuklir
Divisions: Pusat Teknologi dan Keselamatan Reaktor Nuklir
Depositing User: USER PTKRN BATAN
Date Deposited: 14 May 2018 08:50
Last Modified: 14 May 2018 08:50
URI: http://repo-nkm.batan.go.id/id/eprint/1560

Actions (login required)

View Item View Item