UJI KARAKTERISTIK PENCAHAYAAN ILLUMINATOR RADIOGRAFI

Supano, Supano (2011) UJI KARAKTERISTIK PENCAHAYAAN ILLUMINATOR RADIOGRAFI. Widyanuklida, 11 (1). pp. 27-33. ISSN 1410-5357

[img]
Preview
Text
03_UJI_KARAKTERISTIK_PENCAHAYAAN_ILLUMINATOR.pdf

Download (2MB) | Preview

Abstract

Uji Karakteristik Pencahayaan Illuminator Radiografi. Uji karakteristik pencahayaan 5 buah illuminator (viewer) telah dilakukan. Pengujian dilakukan untuk mengetahui karakteristik pencahayaan illuminator radiografi industri. Karakteristik pencahayaan meliputi kecerahan (luminansi), penyebaran (difusi), dan kerataan (uniformity). Uji karakteristik pencahayaan mengacu pada standar SNI-18-6932-2002 menggunakan alat ukur luxmeter EXTECH Model 409026. Hasil uji menunjukkan bahwa illuminator memiliki kecerahan yang berbeda. Kecerahan illuminator memenuhi syarat untuk mengamati radiograf dengan densitas kurang dari 3,0 untuk illuminator nomor 2, densitas kurang dari 3,5 untuk illuminator nomor 1 dan nomor 5, densitas kurang dari 4 untuk illuminator nomor 3 dan nomor 4. Hasil uji penyebaran cahaya menunjukkan semua illuminator memiliki faktor penyebaran melebihi 0,7. Hasil uj i kerataan cahaya menunjukkan bahwa illuminator nom or 4 tidak memenuhi persyaratan. (Luminance Characteristics Testing Of Radiographic Illuminator. The luminance characteristics of five industrial radiographic illuminators have been tested, based on the Indonesian National Standard SNI-J8-6932-2002. The luminance characteristics included brightness, diffusion, and uniformity have been examined using luxmeter EXTECH Model 409026. The results show that the light brightness of illuminators are slightly different. Brightness of illlJ('lina tors are eligible to view the radiograph with density less than 3.0 for number 2 , density less than 3.5 for number J and 5, and density less than 4.0 for number 3 and 4. The light diffusion testing shows that all illuminators have factor of diffusion more than O.7. The Light uniformity testing shows that illuminator number 4 does not meet the requirement.)

Item Type: Article
Uncontrolled Keywords: Radiografi, illuminator (viewer), uji karakteristik pencahayaan, SNI 18-6932-2002.
Subjects: Isotop dan Radiasi > Pemanfaatan Isotop dan Radiasi > Bidang Industri
Divisions: Pusat Pendidikan dan Pelatihan
Depositing User: USER PUSDIKLAT BATAN
Date Deposited: 12 Jun 2019 04:20
Last Modified: 12 Jun 2019 04:20
URI: http://repo-nkm.batan.go.id/id/eprint/308

Actions (login required)

View Item View Item