Abstract

ABSTRAK. TEKNIK ELiMINASI RADIASI LATAR PADA PEMBACAAN DOSIMETER PASIF UNTUK PEMANTAUAN LlNGKUNGAN. Oibahas suatu teknik mengeliminasi sumbangan latar untuk pengukuran peningkatan dosis radiasi yang disebabkan oleh beluk radioaktif atau radiasi terhambur ke permukaan tanah di sekitar fasilitas nukJir dengan menggunakan dosimeter pas if. Untuk mengeJiminasi Jatar, teknik ini memanfaatkan perisai Pb dan lokasi kontrol. Oengan menggunakan dua jenis dosimeter pasif yaitu dosimeter gelas (PLO SC-1) dan dosimeter termoluminesensi (TLO CaSO4:Tm), telah dilaksanakan tiga kali pengukuran paparan radiasi secara bulanan di sekitar tempat penyimpanan Jimbah radioaktif Japan Atomic Energy Research Institute (JAERI) di tapak Oarai dan Tokaimura untuk mengevaluasi kinerjanya. Evaluasi dilakukan dengan cara membandingkan hasilnya terhadap niJai acuan. NiJai acuan diperoleh dari pengukuran menggunakan detektor berbentuk bola Nal(TI) berdiameter 7.5 cm dan fungsi G(E) yang mengkonversi responnya menjadi besaran paparan. Oengan mengoreksi hasil dari TLO sehubungan dengan efek kebergantungan energi, hampir seluruh hasil dari tiga kali pengukurannya sesuai dengan nilai acuan. Oibandingkan dengan TLO, hasiJ yang diperoleh berdasarkan pembacaanPLOlebih mendekati nilai acuan. Teknik ini menjanjikan prosedur sederhana tetapi akurat untuk mengeliminasi J~tar dalam estimasi peningkatan dosis. ABSTRACT. A METHOD FOR SEPARATING BACKGROUND FROM PASSIVE DOSIMETERS READING IN ENVIRONMENTAL MONITORING. A simple method using passive dosemeters for estimating elevated dose in the vicinity of nuclear facility due to downward radiation arising from the plume discharge and direct or scatteredc radiations was presented.. In, eliminating the background this method rely on lead shields and a control location. By using two different types of passive dosemeter, photoluminescence dosemeter (PLD SC-1) and thermoluminescence dosemeter (TLO CaSO4:Tm), three runs of monthly measurement have been performed to evaluate the applicability in isolating the elevated dose at locations close to the radioactive waste storage in the Oarai site and Tokaimura site of the Japan Atomic Energy Research Institute (JAERI). The results obtained were intercompared with the reference values those measured with a 3" ~spherical Nal(TI) detector applying a function G(E). By correcting the results of the TLD by a correction factor associated with the energy dependence effect, almost all of the results of the three runs were in agreement within the limits of uncertainty. Compared with the reference values, the results based on the PLO's reading are closer than those the TLO one. This method provides a simple procedure to eliminate the background dose in estimating the elevated' dose accurately.

Item Type: Article
Subjects: Keselamatan dan Keamanan Nuklir > Keselamatan Lingkungan > Keselamatan Radiasi Lingkungan
Divisions: Pusat Reaktor Serba Guna
Depositing User: EDITOR PRSG BATAN
Date Deposited: 09 Aug 2018 04:19
Last Modified: 09 Aug 2018 04:19
URI: http://repo-nkm.batan.go.id/id/eprint/3678