RANCANG BANGUN ALAT UKUR DENSITAS FILM HASIL RADIOGRAFI

Nurdin, Nurdin (2004) RANCANG BANGUN ALAT UKUR DENSITAS FILM HASIL RADIOGRAFI. Widyanuklida, 5 (1). pp. 13-18. ISSN 1410-5357

[img]
Preview
Text
03_RANCANG_BANGUN_ALAT_UKUR_DENSITAS.pdf

Download (2MB) | Preview

Abstract

Rancang Bangun Alat Ukur Densitas Film Hasil Radiografi. Telah dibuat suatu perangkat pendukung radiografi dengan tujuan untuk mengukur densitas film hasil radiografi dengan menggunakan perangkat komputer. Perangkat keras terdiri dari sensor cahaya, rangkaian pengubah tegangan ke digital dan rangkaian antarmuka, sedangkan perangkat lunak menggunakan bahasa program labVIEW. Sensor cahaya dipasang pada rangkaian pembagi tegangan sehingga tegangan keluaran yang dihasilkan dari rangkaian tersebut besamya berbanding terbalik dengan intensitas cahaya yang mas uk. ADC-0804 digunakan untuk mengubah tegangan analog menjadi digital dan antarrnuka PPI-8255 digunakan untuk berkomunikasi data dengan komputer selanjutnya data diproses oleh perangkat lunak LabVIEW. Data hasil pengukuran intensitas ditampilkan dan diolah secara otomatis menjadi nilai densitas, variasi densitas dan kesimpulan untuk menentukan film hasil radiografi. Hasil pengujian alat ukur densitas film hasil radiografi ini mempunyai persamaan garis lurus Y = 1,08X - 0,827 dan tingkat kesalahan sebesar 7,46 %. (Propotipe Of Radiografhic Fllm Density Apparatus. A propotipe of radiographic apparatus for film density measurement was made and run using a computer. The apparatus consists of a light censor, an analog-to-digital converter (ADC-080 I), and an interface peripheral (PPI-8255). The LABVIEW software was applied to run the system. The light censor absorbed light with different intensity passing through the film. Signals of light were changed to into analog voltages by a voltage divider which was inserted inside the probe. The analog voltages, then, were converted to digital voltages by ADC-080 I. The digital voltages, as computer data inputs, were sent by a programmable input-output (PPI-8255) to a computer. The LAB VIEW software calculated the data and then displayed to a computer monitor. Value of density and variation density can be viewed at the computer monitor, then conclusion can be made. The measurement results have a linear equation: Y=1.08 X + 0.827, where Y = density form measurement and X = density standard from film stepwedge. Relative error of the measurement was 7.16%)

Item Type: Article
Subjects: Isotop dan Radiasi > Pemanfaatan Isotop dan Radiasi > Bidang Industri
Rekayasa Perangkat dan Fasilitas Nuklir > Mekanik dan Struktur > Mekanik
Rekayasa Perangkat dan Fasilitas Nuklir > Elektromekanik dan Kendali > Elektromekanik
Divisions: Pusat Pendidikan dan Pelatihan
Depositing User: USER PUSDIKLAT BATAN
Date Deposited: 04 May 2018 09:12
Last Modified: 04 May 2018 09:12
URI: http://repo-nkm.batan.go.id/id/eprint/413

Actions (login required)

View Item View Item