e-Repository BATAN

Advanced Search

KAJIAN UNJUK KERJA INTERMEDIATE HEAT EXCHANGER PADA SISTEM KOGENERASI REAKTOR VHTR

Ignatius Djoko Irianto, IDI (2009) KAJIAN UNJUK KERJA INTERMEDIATE HEAT EXCHANGER PADA SISTEM KOGENERASI REAKTOR VHTR. KAJIAN UNJUK KERJA INTERMEDIATE HEAT EXCHANGER PADA SISTEM KOGENERASI REAKTOR VHTR. pp. 12-19. ISSN 0854 - 2910

[img]
Preview
Text
02_Ign.Djoko Irianto_12-19_OK.pdf

Download (159kB) | Preview

Abstract

ABSTRAK KAJIAN UNJUK KERJA INTERMEDIATE HEAT EXCHANGER PADA SISTEM KOGENERASI REAKTOR VHTR. Very High Temperature Reactor (VHTR) atau reaktor bertemperatur sangat tinggi adalah salah satu jenis reaktor Generasi IV yang didesain dengan konsep kogenerasi untuk pembangkit listrik dan produksi hidrogen. VHTR berpendingin helium dengan temperatur outlet kurang lebih 1000o C dan bertekanan 7 MPa. Komponen konversi energi yang utama dalam sistem kogenerasi reaktor VHTR adalah Intermediate Heat Exchanger (IHX). Melalui IHX, energi termal dipindahkan dari sistem reaktor ke sistem kogenerasi untuk pembangkitan listrik dan proses produksi hidrogen. Keberhasilan desain reaktor VHTR ditentukan salah satunya oleh unjuk kerja (kinerja) rancangan IHX. Dalam makalah ini, hasil kajian tentang unjuk kerja IHX dalam satu sistem kogenerasi untuk pembangkitan listrik dan produksi hidrogen diuraikan. Unjuk kerja IHX ditentukan (dipengaruhi) oleh beberapa parameter antara lain: keefektifan (efektivitas) IHX, efisiensi IHX, dan konfigurasi IHX dalam sistem kogenerasi. Ada tiga konfigurasi sistem kogenerasi yang dikaji, yaitu: konfigurasi dengan siklus pembangkitan listrik secara langsung tanpa Secondary Heat Exchanger (SHX), konfigurasi sistem pembangkitan listrik secara langsung dengan SHX, dan konfigurasi sistem pembangkitan listrik secara tak langsung. Kajian dilakukan dengan cara membandingkan parameter kinerja IHX dalam tiga konfigurasi sistem kogenerasi. Hasil kajian menunjukkan bahwa efisiensi tertinggi terjadi pada konfigurasi dimana pembangkitan listrik secara langsung dengan SHX dan IHX dipasang secara paralel dengan Plant Heat Exchanger (PHX). Walaupun efisiensinya rendah, konfigurasi ketiga memiliki efektivitas yang tinggi,. Namun demikian, konfigurasi ini dimana pembangkitan listrik dilakukan secara tak langsung berpeluang untuk desain sistem yang lebih kompak. Katakunci : Sistem Kogenerasi VHTR, Intermediate Heat Exchanger (IHX), konfigurasi sistem IHX, efisiensi, keefektifan sistem IHX. ABSTRACT ASSESSMENT OF THE PERFORMANCE OF INTERMEDIATE HEAT EXCHANGER ON VHTR REACTOR COGENERATION SYSTEM. Very High Temperature Reactor (VHTR) is one of Generation IV reactors which is conceptually designed using cogeneration configuration for electric generation and for hydrogen production. VHTR employs a helium-coolant with operating pressure 7 MPa and 1000o C outlet temperature. The main energy conversion component in VHTR cogeneration is intermediate heat exchanger (IHX). Thermal energy passes the IHX from the reactor system to the cogeneration system for electric generation and for hydrogen production. The success of VHTR design is affected by many factors, one of which is the performance of IHX. This paper describes the results of the assessment of IHX performance in VHTR cogeneration system. The performance of IHX is influenced by some parameters such as: effectiveness of IHX, efficiency of IHX, and the configuration of IHX in the cogeneration system. There are three configuration systems assessed: direct cycle with secondary heat exchanger (SHX), direct cycle without SHX, and indirect cycle. The assessment are performed by comparing the parameter of IHX performance in the three configuration systems. The results of the assessment show that the highest efficiency is given by the direct cycle with SHX and the IHX is set in parallel with PHX. Despite its low efficiency, the third configuration obtains the highest effectiveness. This configuration in which electricity is generated indirectly has possibility to be used for a compact system design. Prosiding Seminar Nasional ke-15 Teknologi dan Keselamatan PLTN Serta Fasilitas Nuklir ISSN : 0854 - 2910 Surakarta, 17 Oktober 2009 13 Key words : VHTR cogeneration system, intermediate heat exchanger (IHX), IHX system configuration, IHX efficiency, IHX effectiveness

Item Type: Article
Subjects: Keselamatan dan Keamanan Nuklir
Divisions: Pusat Teknologi dan Keselamatan Reaktor Nuklir
Depositing User: USER PTKRN BATAN
Date Deposited: 09 Nov 2018 08:38
Last Modified: 09 Nov 2018 08:38
URI: http://repo-nkm.batan.go.id/id/eprint/4852

Actions (login required)

View Item View Item