e-Repository BATAN

Advanced Search

EVALUASI DESAIN REAKTOR DAYA GENERASI III+ BERDASARKAN KEJADIAN FUKUSHIMA

D.T. Sony Tjahyani, DTST (2011) EVALUASI DESAIN REAKTOR DAYA GENERASI III+ BERDASARKAN KEJADIAN FUKUSHIMA. EVALUASI DESAIN REAKTOR DAYA GENERASI III+ BERDASARKAN KEJADIAN FUKUSHIMA. pp. 99-110. ISSN 0854-2910

[img]
Preview
Text
01_DT Sony-PTRKN-cd.pdf

Download (231kB) | Preview

Abstract

ABSTRAK EVALUASI DESAIN REAKTOR DAYA GENERASI III+ BERDASARKAN KEJADIAN FUKUSHIMA. Peristiwa Fukushima merupakan kecelakaan parah yang diawali dengan kejadian eksternal secara berturut-turut yaitu gempa dan tsunami sehingga menimbulkan kehilangan daya listrik eksternal dan dilanjutkan dengan Station Blackout (SBO). Reaktor daya yang mengalami kecelakaan di Fukushima merupakan reaktor daya generasi II. Saat ini yang sedang dibangun di dunia adalah termasuk generasi III+ , maka sangat penting untuk mengevaluasi kejadian yang sama terhadap reaktor daya generasi III+ . Makalah ini menentukan beberapa titik lemah fungsi sistem yang terjadi pada peristiwa di Fukushima, selanjutnya dibandingkan hal tersebut pada desain reaktor daya generasi III+ , terutama sebelum terjadinya kerusakan teras. Evaluasi dilakukan dengan analisis pohon kejadian pada peristiwa Fukushima, selanjutnya dibandingkan pada desain reaktor daya generasi III+ serta data kontribusi SBO terhadap frekuensi kerusakan teras. Dari evaluasi menunjukkan terdapat 4 (empat) faktor penyebab kecelakaan yaitu: kehilangan suplai daya listrik offsite, tidak berfungsinya genset karena tsunami, tidak berfungsinya pemindah panas sisa (RHR), dan hilangnya buangan panas akhir (UHS). Hasil evaluasi juga menunjukkan bahwa terjadinya kehilangan suplai daya listrik offsite yang memicu terjadinya kecelakaan parah seperti halnya peristiwa Fukushima sangat kecil probabilitasnya, hal ini karena pada desain sudah mengalami perbaikan dan peningkata sistem keselamatan bila dibandingkan dengan reaktor daya generasi II. Selain itu juga dilakukan penerapan secara ketat terhadap redundansi, keragaman, kemandirian, pemisahan secara fisik serta pemilihan tata letak. Kata kunci: Reaktor daya generasi III+ , Fukushima, SBO. ABSTRACT DESIGN EVALUATION FOR GENERATION III+ POWER REACTOR BASED ON FUKUSHIMA INCIDENT. Fukushima incident is severe accident which is initiated external event respectively. It is earthquake and tsunami, so loss of external power supply is occurred and be continued with Station Black out (SBO). Power reactor which has been accident at Fukushima is generation II power reactor. In the present, reactors are being built in the world are generation III+ power reactor, so it is important to evaluate similar event against generation III+ power reactor. This paper is to determine some weak points of function system at fukushima incident, and further it is compared with design of generation III+ , especially before core damage occcured. Evaluation has been done by event tree analysis (ETA) for fukushima incident, and then it is compared on generation III power reactor design and SBO contribution data to core damage frequency. The evaluation results showed that there are 4 weaks point cause of the accident. That is loss of power offsite, no function diesel generator caused by tsunami, no function residual heat removal (RHR) and loss of ultimate heat sink (UHS). And further, evaluation results showed that loss of power offsite and it initiate severe accident as Fukushima incident is small probability because of design improvement and enhancement for safety system if compared with generation II power reactor. Moreover, It done the application of redundancy, diversity, independent, physical separation and layout selection with robustness. Keywords: Generation III+ power reactor, Fukushima, SBO

Item Type: Article
Subjects: Keselamatan dan Keamanan Nuklir
Divisions: Pusat Teknologi dan Keselamatan Reaktor Nuklir
Depositing User: USER PTKRN BATAN
Date Deposited: 12 Nov 2018 03:54
Last Modified: 12 Nov 2018 03:54
URI: http://repo-nkm.batan.go.id/id/eprint/4919

Actions (login required)