ANALISIS TEGANGAN PIPA COLD LEG PADA SISTEM PENDINGIN PRIMER REAKTOR TIPE PWR

Alim Mardhi, AM and Roziq Himawan, rh (2012) ANALISIS TEGANGAN PIPA COLD LEG PADA SISTEM PENDINGIN PRIMER REAKTOR TIPE PWR. ANALISIS TEGANGAN PIPA COLD LEG PADA SISTEM PENDINGIN PRIMER REAKTOR TIPE PWR. pp. 241-254. ISSN 0854-2910

[img]
Preview
Text
b16_Alim Mardhi dkk-PTRKN - BATAN.pdf

Download (587kB) | Preview

Abstract

ABSTRAK ANALISIS TEGANGAN PIPA COLD LEG PADA SISTEM PENDINGIN PRIMER REAKTOR TIPE PWR. Pipa cold leg adalah bagian sistem perpipaan pendingin primer yang mempunyai fungsi sangat penting terkait prinsip yang mendasar dari keselamatan reaktor. Kerusakan yang terjadi dapat menyebabkan berhentinya operasi reaktor bahkan bencana. Maka evaluasi terhadap integritas struktur dan keandalan komponen pipa cold leg pada saat kondisi operasi harus dilakukan sebagai jaminan terhadap keamanan sistem keselamatan reaktor. Tujuan penelitian ini adalah untuk mendapatkan nilai tingkat keamanan pipa cold leg saat beroperasi pada kondisi desain, operasi normal dan kondisi gempa. Metodologi yang digunakan adalah melakukan perhitungan analisa tegangan berbasis metode elemen hingga menggunakan perangkat lunak PATRAN. Tahapan yang dilakukan adalah membuat model, memasukkan parameter pembebanan, menghitung nilai tegangan intensitas untuk kemudian dibandingkan dengan nilai tegangan yang diizinkan sesuai standar ASME section III. Dari hasil perhitungan diperoleh nilai tegangan intensitas maksimum sebesar 30,8 Ksi pada kondisi operasi desain. Nilai ini masih dibawah tegangan intensitas yang diizinkan yaitu sebesar 36,6 Ksi. Nilai rasio tegangan maksimum hasil perhitungan terhadap tegangan yang diizinkan adalah 84,3%. Dari hasil perhitungan dapat disimpulkan bahwa tingkat keamanan dan integritas struktur komponen pipa cold leg untuk kondisi operasi normal masih dalam batas aman. Kata kunci: Cold leg, Sistem Pendingin Primer, Metode Elemen Hingga, Analisis Tegangan. ABSTRACT STRESS ANALYSIS OF COLD LEG PIPE IN PWR PRIMARY COOLING SYSTEM. Cold leg pipe functions in primary cooling system are very important related to safety principle of nuclear reactor. The breaks of cold leg pipe could be impact to reactor shutdown and even to be a disaster. That is the reason of structural integrity and reliability evaluation in normal condition should be done to guarantee the safe level of reactor safety system. The aim of this research is to get the safety level value of cold leg under design condition, normal operation, and seismic response. The methodology for doing stress analysis is carried out by using computer code base on finite element method PATRAN. The steps are constructing the finite element model, loading input conditions parameter, and accounting the value of stress intensity to compare with allowable stress in ASME code section III. The obtained maximum stress intensity is 30,8 Ksi on design condition which is still below of the allowed stress intensity of 36.6 Ksi. Maximum stress ratio between the counting value and allowed stress is 84.3%. From these results, we can conclude that the safety level of integrity and reliability structure of cold leg pipe is still under the safety level. Keywords: Cold leg, Reactor Cooling System, Finite Element Method, Stress Analysis

Item Type: Article
Subjects: Keselamatan dan Keamanan Nuklir
Divisions: Pusat Teknologi dan Keselamatan Reaktor Nuklir
Depositing User: USER PTKRN BATAN
Date Deposited: 13 Nov 2018 04:18
Last Modified: 04 Dec 2018 04:14
URI: http://repo-nkm.batan.go.id/id/eprint/5020