e-Repository BATAN

Advanced Search

PENGUJIAN TEGANGAN MEKANIK PADA SISI SEKUNDER DESAIN KONDENSOR TIPE KOMPAK

Dedy Haryanto, DH and Kiswanta, KW and Sagino, SG and Riswan Djambiar, RD (2012) PENGUJIAN TEGANGAN MEKANIK PADA SISI SEKUNDER DESAIN KONDENSOR TIPE KOMPAK. PENGUJIAN TEGANGAN MEKANIK PADA SISI SEKUNDER DESAIN KONDENSOR TIPE KOMPAK. pp. 255-266. ISSN 0854-2910

[img]
Preview
Text
b17_Dedy Haryanto dkk - PTRKN - BATAN.pdf

Download (1MB) | Preview

Abstract

ABSTRAK PENGUJIAN TEGANGAN MEKANIK PADA SISI SEKUNDER DESAIN KONDENSOR TIPE KOMPAK. Fasilitas Untai Uji BETA (UUB) adalah sarana eksperimen yang digunakan untuk penelitian dan pemahaman fenomena reflooding yang terjadi pada bundel bahan bakar PWR selama post-LOCA. Kondensor tipe kompak merupakan salah satu komponen fasilitas tersebut. Kondensor ini didesain untuk menggantikan kondensor yang telah ada dimana keuntungan kondensor tipe kompak lebih mudah dalam hal perawatan. Sebelum dilakukan pabrikasi perlu dilakukan pengujian terhadap desain kondensor. Pengujian dilakukan secara simulasi menggunakan software CATIA Versi 5 Release 19. Pengujian dilakukan dalam kondisi tekanan dan temperatur yang berbeda mengacu pada tekanan desain 10 atm dengan temperatur desain 90°C. Hasil pengujian tegangan mekanik terbesar 4,61 x107 N/m2 pada tekanan 10 atm temperatur 90°C. Tegangan mekanik yang dihasilkan dari pengujian secara simulasi relatif lebih kecil dibandingkan dengan yield strength material Stainless Steel 316 yang digunakan sebesar 2,05 x 108 N/m2 . Dengan demikian desain kondensor tipe kompak ini aman untuk digunakan sebagai salah satu komponen UUB sebagai fasilitas penelitian. Kata kunci: kondensor tipe kompak, tegangan mekanik, Stainless Steel 316. ABSTRACT TESTING OF MECHANIC STRAIN AT SECONDARY SIDE OF DESIGN OF COMPACT TYPE CONDENSER. Beta Testing circuit facility (UUB) is supporting facilities for experiment which applied for research and understanding of phenomenon refolding happened at fuel bundle PWR during post-LOCA. Compact type condenser is one of the facility components. The condenser designed to replace condenser which have is where interest of easier compact type condenser in the case of maintenance. Before manufacturing require to be done testing at design of condenser. Test by done simulation apply software CATIA Version 5 Release 19. The test are done condition of different pressure and temperature refers to the design pressure of 10 atm with an design temperature of 90 °C. Result of testing the biggest mechanic strain 4,61 x107 N/m2 at pressure of 10 atm temperature of 90 °C . Result of mechanic strain from test are compared smaller is relative to yield strength material Stainless Steel 316 which applied equal to 2.05 x 108 N/m2 . Compact type condenser design can be used as one of component UUB as research facility, safely. Keywords: compact type condenser, mechanic strain, Stainless Steel 316.

Item Type: Article
Subjects: Keselamatan dan Keamanan Nuklir
Divisions: Pusat Teknologi dan Keselamatan Reaktor Nuklir
Depositing User: USER PTKRN BATAN
Date Deposited: 13 Nov 2018 04:18
Last Modified: 13 Nov 2018 04:18
URI: http://repo-nkm.batan.go.id/id/eprint/5021

Actions (login required)

View Item View Item