e-Repository BATAN

Advanced Search

ANALISIS DESAIN TANGKI TUNDA N-16 SISTEM PENDINGIN RRI MENGGUNAKAN RELAP5

Sukmanto Dibyo, SD (2013) ANALISIS DESAIN TANGKI TUNDA N-16 SISTEM PENDINGIN RRI MENGGUNAKAN RELAP5. ANALISIS DESAIN TANGKI TUNDA N-16 SISTEM PENDINGIN RRI MENGGUNAKAN RELAP5. pp. 245-254. ISSN 0854-2910

[img]
Preview
Text
257-266 Sukmanto Dibyo.pdf

Download (4MB) | Preview

Abstract

ABSTRAK ANALISIS DESAIN TANGKI TUNDA N-16 SISTEM PENDINGIN RRI MENGGUNAKAN APLIKASI RELAP5. Indonesia saat ini memiliki 3 reaktor riset yang akan berakhir masa operasinya, oleh karena itu perlu mewujudkan adanya desain reaktor riset baru berupa desain konseptual Reaktor Riset Inovatif (RRI). Kajian desain sistem pendingin reaktor telah dilakukan untuk komponen utama pada sistem pendingin yaitu kolam reaktor, pompa, penukar panas, tangki tunda, sistem bantu dan menara pendingin. Dalam makalah ini dianalisis desain tangki tunda sistem pendingin RRI dengan mengaplikasikan paket program RELAP5 untuk mendapatkan dimensi tangki yang optimal. Analisis menggunakan model yang terdiri dari 3 tmdpvol, 1 trip-valve, 4 volume pipa, 5 single-volume, 1 tmdpjun dan 9 single-junc. RELAP5 memodelkan pendingin mengalir ke dalam tangki dan diinjeksi oleh air pada temperatur berbeda dengan laju alir 800kg/det. Pemodelan ini merupakan bagian dari model keseluruhan yang sedang dikerjakan untuk jaringan sistem pendingin RRI. Hasil analisis desain tangki tunda RRI menunjukkan dimensi tangki tunda dengan ukuran panjang 7,50 m, diameter 2,50 m, volume 40,88 m3 , diameter nosel 0,75 m dan tangki dilengkapi ellipsoidal heads, dengan dimensi ini peluruhan N-16 adalah 57,5 detik.. Kata Kunci : analisis desain, tangki tunda, N-16, RELAP5 ABSTRACT DESIGN ANALYSIS OF N-16 DELAY TANK FOR RRI COOLING SYSTEM USING RELAP5. Indonesia currently has 3 research reactor which the reactor operation will end, therefore it is necessary to realize the design of a new research reactor i.e. a conceptual design of Innovative Research Reactor (RRI). Design assessment of Reactor coolant system has been performed for the main components in the cooling system i.e. reactor pool, pumps, heat exchangers, tanks delay, auxiliary systems and cooling towers. This paper analyzed the delay tank design of RRI cooling system by applying RELAP5 program to obtain the optimal dimensions of the tank. Analysis using a model consisting of 3 tmdpvol, 1 trip-valve, 4 pipe volume, single-volume 5,1 tmdpjun and 9 single-junc. RELAP5 model the coolant to flow into the tank and injected with water at different temperatures with a flow rate of 800kg/det. This modeling is part of the overall model that is being done to the loop cooling system of RRI. Tank design analysis results showed that dimensions of RRI delay tank are 7.50 m length, 2.50 m diameter, volume 40.88 m3 , 0.75 m diameter nozzle and the tank equipped ellipsoidal heads, with this dimensions the decay of N-16 is 57.5 seconds. Keywords : design analysis, delay tank, N-16, RELAP5

Item Type: Article
Subjects: Keselamatan dan Keamanan Nuklir
Divisions: Pusat Teknologi dan Keselamatan Reaktor Nuklir
Depositing User: USER PTKRN BATAN
Date Deposited: 14 Nov 2018 08:05
Last Modified: 14 Nov 2018 08:05
URI: http://repo-nkm.batan.go.id/id/eprint/5325

Actions (login required)