e-Repository BATAN

Advanced Search

DESAIN AWAL PERISAI RADIASI DAN ANALISIS LAJU DOSIS DI DAERAH KERJA REAKTOR RISET INOVATIF MENGGUNAKAN MCNPX

Amir Hamzah, AH (2013) DESAIN AWAL PERISAI RADIASI DAN ANALISIS LAJU DOSIS DI DAERAH KERJA REAKTOR RISET INOVATIF MENGGUNAKAN MCNPX. DESAIN AWAL PERISAI RADIASI DAN ANALISIS LAJU DOSIS DI DAERAH KERJA REAKTOR RISET INOVATIF MENGGUNAKAN MCNPX. pp. 266-275. ISSN 0854-2910

[img]
Preview
Text
309-318 Tulis Jojo.pdf

Download (5MB) | Preview

Abstract

ABSTRAK DESAIN AWAL PERISAI RADIASI DAN ANALISIS LAJU DOSIS DI DAERAH KERJA REAKTOR RISET INOVATIF MENGGUNAKAN MCNPX. Sesuai dengan renstra PTRKN yang diantaranya adalah diperolehnya desain konseptual reaktor riset inovatif. Dari segi teras reaktor, desain konseptual tersebut meliputi desain teras, desain termohidrolik dan desain perisai radiasi. Tujuan utama dalam penelitian ini adalah desain perisai dan analisis laju dosis radiasi untuk mendapatkan kondisi yang memenuhi batas keselamatan radiasi di daerah kerja reaktor riset inovatif. Analisis laju dosis radiasi dihitung menggunakan paket program MCNPX dengan cara memvariasi tebal dinding dan jenis perisai radiasinya. Dari hasil perhitungan dosis gamma ini bisa dipilih jenis dan tebal perisai radiasi yang diperlukan untuk reaktor riset tersebut berupa beton biasa dengan ketebalan 200 cm. Hasil analisis menunjukkan bahwa desain perisai tersebut menghasilkan laju dosis maksimum 15,34 µSv/jam di dekat dinding perisai radiasi di daerah balai eksperimen. Laju dosis tersebut telah memenuhi batas keselamatan radiasi yang ditentukan oleh Badan Pengawas Tenaga Nuklir (BAPETEN). Kata kunci: Reaktor riset inovatif, perisai radiasi, laju dosis, MCNPX. ABSTRACT RADIATION SHIELD PRELIMINARY DESIGN AND ANALYSIS OF DOSE RATE IN THE WORKING AREA OF INNOVATIVE RESEARCH REACTOR USING MCNPX. In accordance with the PTRKN strategic plan, it was obtained the conceptual design of innovative research reactor. In terms of the reactor core, the conceptual design of the core design, thermohydraulic design and radiation shield design. The main objective of this research is the design of the shield and analysis of radiation dose rate to obtain boundary conditions that meet radiation safety in the work area of innovative research reactor. Analysis of the radiation dose rate is calculated using MCNPX program package by varying the wall thickness and type of radiation shielding. From the calculation of gamma dose can be selected type and thickness of radiation shielding required for a research reactor in the form of ordinary concrete with a thickness of 200 cm. The analysis showed that the shield design produces maximum dose rate 15.34 µSv/ hour in near the shield wall in the experiment hall. The dose rate in compliance with radiation safety limits set by the Nuclear Energy Regulatory Agency (BAPETEN). Keywords: Innovative research reactor, radiation shielding, dose rate, MCNPX

Item Type: Article
Subjects: Keselamatan dan Keamanan Nuklir
Divisions: Pusat Teknologi dan Keselamatan Reaktor Nuklir
Depositing User: USER PTKRN BATAN
Date Deposited: 16 Nov 2018 01:38
Last Modified: 16 Nov 2018 01:38
URI: http://repo-nkm.batan.go.id/id/eprint/5332

Actions (login required)