KOMISIONING INTEGRASI UNTAI UJI BETA (UUB) DENGAN BAGIAN UJI HEATING-02

Kiswanta, KW and Edy Sumarno, ES and Joko Prasetio W, JPW and Ainur Rosidi, AR (2013) KOMISIONING INTEGRASI UNTAI UJI BETA (UUB) DENGAN BAGIAN UJI HEATING-02. KOMISIONING INTEGRASI UNTAI UJI BETA (UUB) DENGAN BAGIAN UJI HEATING-02. pp. 353-364. ISSN 0854-2910

[img]
Preview
Text
365-376 Kiswanta.pdf

Download (8MB) | Preview

Abstract

ABSTRAK KOMISIONING INTEGRASI UNTAI UJI BETA (UUB) DENGAN BAGIAN UJI HEATING-02. Telah dilakukan komisioning hasil integrasi Untai Uji BETA dengan HeaTiNG-02. Untai Uji BETA (UUB) merupakan fasilitas penelitian yang digunakan sebagai pendukung untuk eksperimen simulasi kecelakaan reaktor. Dalam rangka mendukung eksperimen studi perpindahan panas pada celah sempit dimensi pelat, UUB membutuhkan HeaTiNG-02 untuk bagian ujinya. UUB diinterintegrasi dengan HeaTiNG-02 bertujuan agar mampu digunakan untuk eksperimen perpindahan panas pada celah sempit dimensi pelat dengan variasi debit aliran dan suplai air pendingin yang tidak terbatas. Integrasi dilakukan dengan memodifikasi pemipaan baru sistem primer dan sekunder UUB, sistem instrumentasi dan sistem kelistrikan. Sedangkan komisioning dilakukan untuk menguji dan melakukan eksperimen sejauh mana hasil modifikasi dapat sesuai dengan desain yang telah dilakukan. Pengujian dilakukan dengan menghitung rugi-rugi tekanan dan laju alir pada kondisi dingin dan pemanasan dengan temperatur 40°C, 50°C dan 60°C. Hasil kegiatan modifikasi Untai Uji BETA terintegrasi dengan HeaTiNG-02 adalah masih dalam tahap komisioning dan eksperimen awal untuk menentukan karakteristiknya. Dari pengujian awal fasilitas ini mampu digunakan untuk eksperimen studi perpindahan panas pada celah sempit dimensi pelat dengan kondisi loop tertutup dengan kerugian total tekanan diperoleh formulasi ∆Ptotal = -0,00663 + 89,1169 Q + 1,02.106 Q2 bar untuk kondisi dingin dan ∆Ptotal = -0.00313 + 62.41545 Q + 1.025x106 Q2 bar untuk kondisi panas. Kata Kunci : Untai Uji BETA, HeaTiNG-02, integrasi ABSTRACT COMMISSIONING FOR INTEGRATION BETA TEST LOOP (UUB) WITH THE HEATING-02 TESTING BUNDLE. Have performed commissioning for integration results BETA test loop with HeaTiNG02. BETA test loop(UUB) is a research facility that is used as a support for the experimental reactor accident simulation. In order to support the experimental study of heat transfer in a narrow slit plate dimensions, requiring HeaTiNG-02 for part of the test. UUB integrated with HeaTiNG-02 aims to be able to be used for experiments on the heat transfer plates with narrow gap dimensions and flow rate variation cooling water supply is not unlimited. Integration is done by modifying the new piping system of primary and secondary of the UUB, instrumentation systems and electrical systems. While commissioning performed to test and experiment the extent to which the results can be modified according to the design that has been done. Testing is done by calculating the pressure loss and flow rate in cold and warm conditions with a temperature of 40°C, 50°C and 60°C. Test results of the modified BETA test loop integrated with HeaTiNG02 is still in the commissioning phase and initial experiments to determine its characteristics. From the initial testing of this facility can be used to study heat transfer experiments on plates with narrow gap dimensions closed loop conditions with total pressure loss formulations obtained ∆Ptotal = -0.00663 89.1169 + Q + Q2 1,02.106 bar for cold conditions and ∆Ptotal = -0.00313 62.41545 + Q + Q2 1.025x106 bar for hot conditions. Keywords : BETA Test Loop, HeaTiNG-02, integration

Item Type: Article
Subjects: Keselamatan dan Keamanan Nuklir
Divisions: Pusat Teknologi dan Keselamatan Reaktor Nuklir
Depositing User: USER PTKRN BATAN
Date Deposited: 16 Nov 2018 01:38
Last Modified: 16 Nov 2018 01:38
URI: http://repo-nkm.batan.go.id/id/eprint/5357

Actions (login required)

View Item View Item