e-Repository BATAN

Advanced Search

KAJIAN PENGARUH KELEMBABAN PADA PENGUKURAN SENSOR DETEKTOR FLUKS NEUTRON RSG-GAS. (Kiswanta1, Sudarno1, Sujarwono2, Ranji Gusman2, Heri Suherkiman2 1 Pusat Teknologi dan Keselamatan Reaktor Nuklir (PTKRN) – BATAN 2 Pusat Reaktor Serba Guna (PRSG) - BATAN Email : kiswanta-igos@batan.go.id)

Kiswanta, KW and Sudarno, SD and Sujarwono, Sujarwono and Ranji Gusman, RG and Heri Suherkiman, HS (2019) KAJIAN PENGARUH KELEMBABAN PADA PENGUKURAN SENSOR DETEKTOR FLUKS NEUTRON RSG-GAS. (Kiswanta1, Sudarno1, Sujarwono2, Ranji Gusman2, Heri Suherkiman2 1 Pusat Teknologi dan Keselamatan Reaktor Nuklir (PTKRN) – BATAN 2 Pusat Reaktor Serba Guna (PRSG) - BATAN Email : kiswanta-igos@batan.go.id). In: Prosiding Seminar Nasional Teknologi Energi Nuklir 2019, 18 September 2029, Universitas ANDALAS Fakultas Teknik Padang Sumatera Barat.

Full text not available from this repository.

Abstract

ABSTRAK KAJIAN PENGARUH KELEMBABAN PADA PENGUKURAN SENSOR DETEKTOR FLUKS NEUTRON RSG-GAS. Reaktor Serba Guna GA. Siwabessy (RSG-GAS sudah beroperasi lebih dari 30 tahun. Faktor kelembaban dapat menyebabkan terjadi pergeseran nilai sinyal pada pengukuran bagian analog, degradasi komponen, korosi bahkan sering mengalami kerusakan. Kerusakan tersebut menyebabkan pengukuran tidak tepat dan mempengaruhi sinyal-sinyal RPS. Juga menyebabkan unbalance, proses balance menjadi lebih lama bahkan scram. Untuk itu perlu dilakukan kajian pengaruh kelembaban terhadap proses pengukuran pada detektor fluks neutron RSG-GAS. Kajian meliputi kondisi titik pengukuran, transduser, defais, perangkat dan tampilan baik secara visual, sinyal listrik, karakteristik sinyal, ketelitian, kestabilan, error, dan pengaruh lingkungan. Metode penelitian dilakukan dengan mengukur tingkat kelembaban, pemberian semburan udara SCA ke dalam detektor guide tube untuk mengurangi kelembaban, mengukur sinyal listrik pada setiap bagian analog dan menganalisis pengaruh kelembaban terhadap rangkaian pengukuran detektor fluks neutron. Dari data bagian detektor fluks neutron tersebut dievaluasi untuk mendukung kajian teknis penuaan RSG-GAS. Hasil pengukuran tingkat kelembaban pada pengukuran fluks neutron RSG-GAS sudah dapat dilakukan dengan baik. Pengaruh kelembaban udara sangat signifikan terhadap hasil pengukuran sinyal listrik. Pemberian udara kering dari kompressor ke dalam guide tube detektor neutron terbukti sangat efektif untuk menurunkan kelembaban udara dari sekitar 62% menjadi 6% sedangkan temperatur tetap sekitar 21-22°C. Sedangkan tingkat kestabilan sistem dan ketelitian bagian penguat amplifier masing-masing detektor fluks neutron masih bagus sekitar 98%. Kata kunci: Detektor fluks neutron, pengukuran, kelembaban, sinyal listrik, degradasi. ABSTRACT STUDY OF HUMIDITY EFFECT FOR THE NEUTRON FLUKS DETECTORS MEASUREMENT OF RSG-GAS. The GA Multipurpose Reactor. Siwabessy (RSG-GAS has been operating for more than 30 years. The moisture factor can cause a shift in signal values in analog section measurements, component degradation, corrosion and even damage. The damage causes improper measurement and affects RPS signals. Also causes unbalance the balance process takes longer and even scams, so it is necessary to study the effect of humidity on the measurement process on RSG-GAS neutron flux detectors.The study includes conditions of measurement points, transducers, defects, devices and displays both visually, electrical signals, signal characteristics accuracy, stability, error, and environmental influences.The research method was carried out by measuring the moisture level, giving SCA air bursts into guide tube detectors to reduce humidity, measuring electrical signals in each analog section and analyzing the effect of humidity on the neutron flux detector measurement circuit. da The neutron flux detector section was evaluated to support the technical review of aging RSG-GAS. The results of the measurement of the level of moisture in the measurement of RSG-GAS neutron flux can be done well. The effect of air humidity is very significant on the results of measuring electrical signals. Giving dry air from the compressor to the neutron detector guide tube proved to be very effective in reducing air humidity from about 62% to 6% while the fixed temperature was around 21-22 ° C. While the level of system stability and accuracy of the amplifier amplifier parts of each neutron flux detector is still good at around 98%. Keywords: Neutron flux detector, measurement, humidity, electrical signal, degradation.

Item Type: Conference or Workshop Item (Paper)
Subjects: Keselamatan dan Keamanan Nuklir
Divisions: Pusat Teknologi dan Keselamatan Reaktor Nuklir
Depositing User: USER PTKRN BATAN
Date Deposited: 07 Jul 2020 06:22
Last Modified: 07 Jul 2020 06:22
URI: http://repo-nkm.batan.go.id/id/eprint/9872

Actions (login required)

View Item View Item