e-Repository BATAN

Advanced Search

PENENTUAN DAMPING OPTIMAL FLOWMETER ULTRASONIK PADA FASILITAS EKSPERIMEN REACTOR CAVITY COOLING SYSTEM (RCCS) (Sudarno, Kiswanta, Arif Adtyas Budiman)

Sudarno, SD and Kiswanta, KW and Arif Adtyas Budiman, AAB (2019) PENENTUAN DAMPING OPTIMAL FLOWMETER ULTRASONIK PADA FASILITAS EKSPERIMEN REACTOR CAVITY COOLING SYSTEM (RCCS) (Sudarno, Kiswanta, Arif Adtyas Budiman). In: Seminar Nasional Teknologi Energi Nuklir 2019 Padang, 18 September 2019 309 ISSN: 2355-7524, 18 September 2019, Universitas ANDALAS - PADANG-SUMETERA BARAT.

Full text not available from this repository.

Abstract

ABSTRAK PENENTUAN DAMPING OPTIMAL FLOWMETER ULTRASONIK PADA FASILITAS EKSPERIMEN REACTOR CAVITY COOLING SYSTEM (RCCS). RCSS adalah sistem keselamatan pasif pada reaktor nuklir temperatur tinggi yang didesain untuk menghilangkan panas dan menjaga temperatur tangki reaktor dan struktur reaktor tetap dalam batas keselamatan. Satu fasilitas eksperimen RCCS telah dibangun di Pusat Teknologi dan Keselamatan Reaktor (PTKRN) BATAN, untuk memverifikasi desain Reaktor Daya Non Komersial (RDNK) tipe HTGR. Pengukuran laju alir dalam RCCS menggunakan flowmeter ultrasonik menghasilkan derau yang signifikan. Untuk mengatasi hal tersebut ditambahkan damping pada sistem instrumentasi pengukuran laju alir. Tujuan dari penelitian ini adalah untuk menentukan nilai damping optimal untuk ultra sonic flowmeter pada fasilitas eksperimen RCCS. Metoda yang dilakukan adalah dengan melakukan analisis sinyal pengukuran laju alir, untuk mengetahui pengaruh damping terhadap waktu tunda dan nilai Signal to Noise Ratio (SNR). Dari hasil analisis terbukti bahwa penambahan damping dapat meningkatkan nilai SNR, tetapi memberikan dampak bertambahnya waktu tunda sensor. Dari hasil eksperimen diperoleh nilai damping optimal pada flowmeter ultrasonik adalah antara 5 detik sampai dengan 10 detik. Kata kunci: damping, optimal, flowmeter ultrasonik, RCCS. ABSTRACT DETERMINATION OF OPTIMAL DAMPING OF ULTRASONIC FLOWMETER FOR REACTOR CAVITY COOLING SYSTEM (RCCS) EXPERIMENT FACILITIES. RCSS is a passive safety system in a high temperature nuclear reactor designed to remove heat and keeps temperature of reactor pressure vessel and the containment structure remains within the safety limit. An RCCS experiment facility has been constructed at the Center for Nuclear Technology and Safety (PTKRN) BATAN, to prove the design of the HTGR-type Experimental Power Reactor (RDNK). The flow rate measurement of the RCCS coolant circulation was done using an ultrasonic flowmeter, which produced significant noise. To overcome this, the attenuation of the instrumentation system for measuring the flow rate was added. The purpose of this study is to determine the optimal damping value of the ultrasonic flowmeter. The method that is carried out was by performing analysis of flowmeter measurement signal at different damping values. This signal analysis includes the effect of damping on the delay time and Signal to Noise Ratio (SNR). The analysis result showed that the addition of damping could increase the SNR value, but increased the time delay of sensor. From the experiment results, we found the optimal damping value for the ultrasonic flowmeter was between 5 and 10 seconds. Keywords: damping, optimal, ultrasonic flowmeter, RCCS

Item Type: Conference or Workshop Item (Paper)
Subjects: Keselamatan dan Keamanan Nuklir
Divisions: Pusat Teknologi dan Keselamatan Reaktor Nuklir
Depositing User: USER PTKRN BATAN
Date Deposited: 23 Jul 2020 08:45
Last Modified: 23 Jul 2020 08:45
URI: http://repo-nkm.batan.go.id/id/eprint/9900

Actions (login required)

View Item View Item